ROCKSOLAR 12V RV Power Kit | Victron MultiPlus-II 3000VA + 400Ah LiFePO4
Backordered — Accept Pre-Order
Couldn't load pickup availability
Description
Description
Run compatible 120 V RV appliances from a 12 V battery bank and recharge when shore power is available. This power kit combines a Victron MultiPlus-II 12/3000/120-50 2x120V inverter/charger with two heated ROCKSOLAR 12.8 V 200 Ah LiFePO4 batteries. In parallel, the batteries provide 400 Ah at 12.8 V nominal, or 5.12 kWh of nominal energy.
What’s included
- 1 × Victron MultiPlus-II 12/3000/120-50 2x120V inverter/charger
- 2 × ROCKSOLAR RV Series 12.8 V 200 Ah self-heating LiFePO4 batteries
- 3 sets of 16-inch 2 AWG battery cables (16 inches per cable)
- 1 × 500 A battery bus bar
Features and specifications
- 3,000 VA pure sine wave inverter. Victron rates this unit for 2,400 W continuous output at 25°C. In battery mode it supplies 120 V AC loads on both legs of a compatible RV panel. A 240 V load requires a compatible 120/240 V split-phase AC input for pass-through.
- 120 A battery charger and 50 A transfer switch. Victron PowerControl limits draw from the AC source. PowerAssist can supplement shore or generator power on L1 with battery power during short demand peaks.
- Two heated batteries with Bluetooth. Each battery stores 2.56 kWh nominal and includes a built-in battery management system. Each is rated for 150 A maximum continuous discharge and more than 6,000 cycles at 0.5C, 80% depth of discharge and 25°C.
Warranty and certification
- Victron inverter/charger: 5-year standard limited warranty under the Victron warranty policy. This inverter model is covered by Victron’s UL 458 conformity certificate.
- ROCKSOLAR batteries: 10-year limited warranty on each battery under the ROCKSOLAR Warranty Policy. Each battery enclosure is rated IP65.
For warranty service, contact ROCKSOLAR support with your order number and the affected component’s serial number.
Installation and DC cabling
Installer-supplied inverter DC leads and DC fuse are required. The 16-inch 2 AWG cables are included as battery interconnect accessories. Use inverter DC leads sized to the Victron installation manual. Have a qualified installer verify the cable and bus bar layout, overcurrent protection, battery current limits and charging settings. The batteries specify 14.0–14.4 V charging voltage and recommend 60 A per battery. Install the IP22 inverter in a dry, ventilated location.
Shipping & Returns
Shipping & Returns
- Shipping: Orders are processed within 1–2 business days. Standard delivery takes 3–7 business days depending on your location.
- Returns: You may return or exchange products within 30 days of receiving your order. Items must be in original condition with proof of purchase.
- If your item is defective or damaged due to manufacturing issues, we’ll gladly replace it at no additional cost.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.